2018-02-27model: Added support for ArbOS from Arbor Networks. (#1096)Jason Ackley
* Basic support for ArbOS from Arbor Networks. ArbOS is the generic name for Arbor Networks (https://www.arbornetworks.com/) OS that runs on some of their devices. Found and imported from https://github.com/claranet/oxidized . Credit to Claranet for the creation. Locally validated on Peakflow SP v8.2+ The module is quite simple as the command 'config show' automatically disables pagination. There is a pagination-enabled version of the command as well. * Added model notes for ArbOS
2018-02-27Added model to Supported-OS-TypesNeil Lathwood
2018-02-21rebasedNeil Lathwood
2018-02-21model: Update br6910 model prompt detection (#1188)dhooper6430
The BR6910 switch can be configured to display anything on the prompt, by default it's vty-, I have modified the prompt statement to allow for whatever the user has configured the prompt to be.
2018-02-15docs: Added model note for 3com comware (#1186)Neil Lathwood
2018-02-10mode: Procurve model add show commands (#1176)Dave
Sanitized output: ``` Power Supply Status: PS# Model State AC/DC + V Wattage ---- --------- ------------- ----------------- --------- 1 Unknwn Powered AC 220V 1500 2 Unknwn Powered AC 220V 1500 2 / 2 supply bays delivering power. Total power: 3000 W ``` Of course you see `unknwn` but that is addressed in latest firmware release. Thanks!
2018-02-10fix: Fixed docker build (#1181)Charlie Allom
2018-02-09model: AWOS Make the space between # mandatory rather than optional in the ↵Thane Gill
prompt. (#1182) Per discussion in #1000
2018-02-05Added support for setting ssh auth methodsNeil Lathwood
2018-02-01removed return characters, fixing the tableKodApa85
2018-02-01Fixed privilege table not displaying correctlyCppMonkey
2018-02-01Initial commit for SSH/Telnet on Xyzel XGS4600 seriesCppMonkey
2018-01-31model: Add show system command to ciscosmb (#1165)Dave
* Add show commands to ciscosmb * Update ciscosmb.rb Uptime changes which cause oxidized to update config. Removing line from final config output
2018-01-30Fix prompt pattern for firewareos clusters and standaloneAlexandre-io
2018-01-25fix: Don't post diff to Slack if there are no diffs (#1151)Adam Smith
2018-01-25model: Fixed FTP Passive/Active modes & Xyzel XGS4600 series Docs (#1161)KodApa85
* FTP Passive/Active mode added * Documentation for Xyzel XGS4600 series
2018-01-18docs: Added documentation for setting up JunOS with Oxidized (#1155)KodApa85
2018-01-14fix: Allow Oxidized service to be stopped from services. (#1144)mattie47
There is an issue with oxidized and correctly terminatating when a user stops the service. Unfortunately the root cause of this issue has yet to be identified, and it may have to do with specific versions of Ruby gems. As such, the workaround is to use a SIGKILL to kill the oxidized/puma service instead of a SIGINIT. Note: This does not solve the issue with manually starting the oxidized daemon and using Ctrl + c to stop it. The solution here is to then press Ctrl + Z, then manually "kill -9 <PID>".
2018-01-09model: Remove system comment on time based rules for RouterOS. (#1143)Alan Gregory
2018-01-06model: Added Allied Telesis AW+ model (#936)mattie47
* Create awplus.rb Added support for Allied Telesis AW+ switches and routers * Add support for Allied Telesis Alliedware Plus products * Add Allied Telesis to Supported Products * Add Allied Telesis to supported models Feature support included: - Telnet and SSH -- Enable/Secret Password - Device info from "show system" command -- Dynamic output e.g. Device Uptime is removed. - Var: remove_secret - User-defined terminal length -- User is not required to "terminal no length" and can keep configured pager length.
2017-12-31Create snr.rbIlya Demyanov
2017-12-15model: Update fortios.rb (#1047)sfini
* Update fortios.rb Modify script for discard changes private key encryption every time config is downloaded https://github.com/ytti/oxidized/issues/931 * Update fortios.rb * Update fortios.rb * Update fortios.rb Added filter for inter-controller-key and Cluster uptime. After update to version 5.6 inter-controller-key change every time config is downloaded . Cluster uptime is now present and change every time config is downloaded . * Update fortios.rb Added rsso secret configuration remove * Update fortios.rb Added (Virus-DB|Extended DB|IPS-DB|IPS-ETDB|APP-DB|INDUSTRIAL-DB|Botnet DB|IPS Malicious URL Database) to the script , as suggested in #1119
2017-12-10mode: Hide snmp community for IOS (#1077)Bruno Brito Carvalho
* Hide snmp community Community is displayed next to this line (old ios versions) * Updating as suggested Thanks @ZacharyPuls * Was missing a / * Was missing the last / I missed that one yesterday. Sorry, making those changes from browser, many useless commits.
2017-12-10model: Add support for Broadband Network Platform Software from GCOM ↵Frederik Kriewitz
Technologies Co.,Ltd. (#1097) * Add support for Broadband Network Platform Software from GCOM Technologies Co.,Ltd. * requested changes
2017-12-04model: Added support for SLX-OS (#1056)Mikaël Mantel
* Add support for SLX-OS * Remove commented code * Add SLX-OS on the list of Supported OS Types * Replace tabs with spaces * Regex modification for remove the display of uptime
2017-11-29docs: Create AireOS.md (#1116)JBBR
2017-11-23fixed csv source (#1113)Neil Lathwood
2017-11-22fix: GPG bug fix when loading file (#1109)Michael Baker
* GPG bug fix * Update Sources.md * Update README.md
2017-11-21Update Sources.mdNeil Lathwood
2017-11-21model: Added support for Opnsense (#1111)pv2b
* Add OPNsense model * Fix class name * Mention support for OPNsense in Supported OS types
2017-11-20feature: Added model information to exec hook (#1105)pv2b
* Add OX_NODE_MODEL to exec hook * Update docs to reflect added OX_NODE_MSG to hook
2017-11-18model: Procurve Handle switch selection for stack commanders (#1104)pv2b
When trying to connect to a HP Procurve Switch with stacking enabled, you are asked to choose which switch to connect to to manage. This patch makes it so that if this question is encountered, just press "Enter" to choose the stack commander. This won't make backing up stack members work (they still need to be configured seperately and given IP addresses, making stacking useless) but at least it makes it possible to back up a commander in a stack seperately. Fixed #1070 Credit to @stiltzkin10 for this fix.
2017-11-18docs: Misc Doc updates (#1107)Jason Ackley
* Move VRP-Huawei.md to new Model-Notes subdir * Update Sources.md with a few improvements: 1. Sync the example table name between the MySQL and SQLite example configs for consistency. 2. Document the very useful custom SQL query parameter (query:) including a couple of examples. * Basic README.md for Model-Notes directory with a simple table for notes/caveats * Markdown quote the Huawei config blocks and link back to README.md * Update Sources.md
2017-11-15fix: Netgear model: Permit . as valid character in prompt (#1099)pv2b
2017-11-11fix: Fix prompt pattern for model/comware.rb to handle ASCII Bell response ↵Nicholas Meredith
+fix minor README.md typo (#1094) * comware.rb: update prompt to work when trailing ^G ASCII 7 (bell) is sent * README.md: correct typo 'HTT' to 'HTTP' for Configuration / Outputs paragraph * model/comware.rb: cleaning out some comments
2017-11-10updated to check if node_wantlaf
2017-11-10Added sql support for calling for single hostlaf
2017-11-10Added support for sending single node request to http sourceNeil Lathwood
2017-11-09docs: Added comment to clarify interval value is in seconds (#1093)Neil Lathwood
2017-11-09Update Hooks.md (#1092)Neil Lathwood
2017-11-09feature: Slack hook - optionally disable diff snippets and post custom ↵Nat Morris
messages (#763) * continue to diffs by default, but optionally post formatted messages * updated readme * remove static channel name * Update Hooks.md
2017-11-08feature: Added hook for XMPP MUC (#951)mortzu
* Added hook for XMPP MUC * Updated dockerfile * Added timeout to prevent oxidized to stop on XMPP error * Updated README
2017-11-05docs: Added changelog for 0.21.0 (#1085)Neil Lathwood
2017-11-01release: Bump version to 0.21.0 (#1081)0.21.0Neil Lathwood
2017-10-30docs: Added help section to docsNeil Lathwood
Added help section to docs
2017-10-24fix: Fixed fiberdriver recording changed output unnecessarily Neil Lathwood
Fixed ever-changing output in fiberdriver model
2017-10-21docs: Fixed the links to the OS filesNeil Lathwood
docs: Fixed the links to the OS files
2017-10-21docs: Fixed the links to the OS fileslaf
2017-10-20Fixed ever-changing output in fiberdriver modelEric Lindsjö
2017-10-17Handle Dell N2000 switches (dnos6)Rémi Verchère