summaryrefslogtreecommitdiff
path: root/lib/oxidized/model
AgeCommit message (Collapse)Author
2017-03-28added support for VTPRobert Drake
2017-03-28Remove single line 'Up Time' lines from show systemnesteffe
2017-03-23Adding support for more "show version" commandsRobert Drake
This is a port of some of the rancid "show version" parsing. I tried to simplify it from the way rancid does it, so it doesn't attempt to guess the device type, but it does provide IOS version and the type of processor.
2017-03-22Fix alvarion block issueSchylar Utley
2017-03-16Do not comment out result for show configuration.Everton Marques
2017-03-16Support for Cisco NGA.Everton Marques
2017-03-07Merge pull request #757 from crami/masterytti
added model for OneAccess OneOS Voice Gateways/Routers
2017-03-07added model for OneAccess OneOS Voice Gateways/RoutersMatthias Cramer
Slight modifications to gemspec for newer ssh gem and correct telnet syntax
2017-03-07Added lines to ignore for SAOS7 devics.Max Mudde
2017-03-06Update saos.rbmakzdot
This proposed change is to make shure lines starting with "! Created: " are ignored. This preventes a diff in the config every time oxidized runs over Ciena SAOS devices. This is probably not the most elegant way but it's a start.
2017-03-06Update regexp to match pfSense 2.3.3 config filessorano
Fix regexp for pfSense (2.3.3-RELEASE) to remove revision time in config pull. Also remove snort last_rule_upd_time in config pull.
2017-03-05Merge pull request #752 from electriceel1985/mellanox_workytti
make mellanox config versioning much less noisy
2017-03-03make mallanox config versioning much less noisycpk
2017-03-01traffic.conf and ports.conf are important configuration files that should be ↵cpk
backed up
2017-02-27Fixed issues with HP Aruba 2530 fw 16.02.0016Mk-
2017-02-22Update to rogue AP filteringRoss W
2017-02-22Updates to ASA secret filteringRoss W
2017-02-21Fix for foundry/jetcore username prompt on telnetf0rkz
2017-02-20Added license information and gsub to take out chatty subscriber license ↵Tim Pozar
updates.
2017-02-20Merge pull request #687 from nertwork/masterytti
Node - Cumulus additional params
2017-02-19Update cumulus.rbJames Farr
2017-02-17add software versionbyq
added software version
2017-02-16Merge pull request #728 from mediumo/tplinkytti
Tplink model
2017-02-16changed README and enable behaviour to cmd instead of sendroot
2017-02-16added variable fortios_autoupdate, to control inclusion of autoupdate messagesroot
2017-02-16added tplink modelroot
2017-02-16added psk and private-key removal to secret sectionroot
2017-02-14Updated timos.rb to ignore "Generated" and "Finished" lines so it doesn't ↵Tim Pozar
look like a new config each time to crawls the box.
2017-02-14Update opengear.rbboudreau
With new update : OpenGear/CM71xx Version 3.16.6u1 e02e2d59 -- Mon Nov 14 17:44:05 EST 2016 the backup wasn't working anymore, needed a prompt
2017-02-10nxos.rb: Add secret blockDave
Took config from our local setup. Adding since it does not have it
2017-02-10Merge pull request #712 from Ultra2D/issue-681ytti
Procurve convert next line (NEL) to new line
2017-02-10Procurve convert next line (NEL) to new lineUltra2D
2017-02-10Remove (some) secrets from Comware configUltra2D
2017-02-07Merge branch 'master' into ArubaIAP_MASTim Pray
2017-02-07Better notes and fix a mistake in the secret linesTim Pray
2017-02-07Modify to support IAP, Instant Controller and Mobility Access SwitchesTim Pray
2017-02-06changed "diagnose autoupdate version" behaviour, since with every update of ↵root
signatures the config version is changed
2017-02-06nicer regex for both password variants of fortiOSroot
2017-02-06added secret removal for fortiOSroot
2017-02-04Cleaner way to fix older IronWare devicesJason Wendel
This works on older IronWare devices without needing a sleep between each command.
2017-02-03Restore compatibility with older versions of IronWareJason Wendel
Remove \r from the "enable" command. Both \r and \n are interpreted the same on older versions, causing a blank line to be sent as the enable password. Add a delay between the sending of the "logout" command and each "exit" command. Older devices don't seem to be able to keep up with the speed the commands are sent without a delay.
2017-02-03Update fabricos.rbK. Gasso
Ignore Uptime/Power/Date fields in chassisShow and configShow
2017-01-31Filter out rogue client alerts from AireOSRoss W
2017-01-24Don't show error is unsupportedvppencilsharpener
This is the proposed fix for issue #669. Let me know if there is anything that I need to fix. This appears to be working correctly for the switch I have in house (S2400-24P). However the model is not working for the Aruba Instant AP (IAP) (virtual) controller. I hope to submit a fix for those once I have it working. The problems with that device appear to be unrelated to these changes as the prompt is incorrect.
2017-01-19Tweak the white space for cleaning.vppencilsharpener
2017-01-18Update ironware.rbdevicenull
Some Brocade devices only have two possible fan speeds. Previously, this only handled three levels of fan speeds. Updated regex will handle both of these cases: Fan 1 ok, speed (auto): 1<->[[2]] Fan 1 ok, speed (auto): 1<->[[2]]<->3
2017-01-11Ignore fan speed changes for ironwaredevicenull
Brocade ICX/FCX log fan speed changes like this: Fan ok, speed (auto): 1<->[[2]]<->3 Fan ok, speed (auto): [[1]]<->2<->3 Remove the current fan speed from the configuration to prevent lots of useless changes from being logged.
2017-01-10Ensure config gets returned even if no replacements are donedevicenull
2017-01-10Mask out configuration date for fiberdriverdevicenull
Our fiberdriver devices report a timestamp during 'show running-config', which results in a config diff on every run. This patch removes the '+! Configuration saved on 2017/01/10 14:21:20' line from the config, as well as a couple other useless status messages
2017-01-10Add support for telnetJason Lixfeld