Age | Commit message (Collapse) | Author | |
---|---|---|---|
2015-04-21 | Fix pre_logout in case the configuration is not saved and ScreenOS asks for ↵ | rivo nurges | |
confirmation | |||
2015-04-21 | Fix screenos prompt regex | rivo nurges | |
2015-04-20 | Merge pull request #107 from FlorianDoublet/ironwareModif | ytti | |
Added a less strict prompt | |||
2015-04-20 | Added a less strict prompt | florian | |
Added less strict prompt | |||
2015-04-17 | Merge pull request #106 from FlorianDoublet/ironwareModif | ytti | |
Changed prompt (too strict) | |||
2015-04-17 | Changed prompt (too strict) | florian | |
Changed prompt (too strict) | |||
2015-04-16 | Merge branch 'master' of https://github.com/ytti/oxidized | Saku Ytti | |
2015-04-16 | add StringScanner | Saku Ytti | |
there are numerous use-cases for this in models, no point to load in models separately | |||
2015-04-16 | Add support for PowerConnect 62xx | Tom Laermans | |
The pager prompt on the PowerConnect 62xx family does not have a leading space; fixed the expect regex. Also added 6224/6248 to the block ignore regex. | |||
2015-04-16 | Add support for HP Comware SMB switches | Tom Laermans | |
Some SMB HP switches (V1910, V1920) run Comware, but have the CLI hidden behind a "secret" toggle - it needs to be activated by _cmdline-mode on. The password to enable it varies per model, so this patch introduces a new var, comware_cmdline to contain the password. Unfortunately we cannot easily autodetect this, as only the "summary" command can give us the model number, but this command is paged and we cannot disable the pager until we are in the full CLI. Tested on HP V1910-24G-POE. | |||
2015-04-14 | Merge pull request #103 from FlorianDoublet/ironwareModif | ytti | |
Add a pre_logout for some devices | |||
2015-04-14 | Add a pre_logout for some devices | florian | |
Add an other post_login for some devices and a pre_logout | |||
2015-04-14 | Add the Cumulus feature | florian | |
Add the Cumulus feature Add Cumulus feature | |||
2015-04-10 | ironware model improvement | florian | |
2015-04-08 | Merge pull request #100 from rodecker/master | ytti | |
hide enable secret when remove_secret is enabled | |||
2015-04-08 | hide enable secret when remove_secret is enabled | Martin Pels | |
2015-04-01 | Add match for 35xx Switches, tidy up regex | MrRJ45 | |
Added a check for 35xx switches Also extract only on the model number, not the suffix (P or F) as we dont need that. | |||
2015-03-30 | PowerConnect Model not skipping some details | MrRJ45 | |
Some PowerConnect models were skipping fine as "Uptime" for example is shown across one line. Some models show this as a heading, and then lines for each stack member and so this was being included in the configuration. This will skip that "section" which is terminated by the next blank line. | |||
2015-03-26 | rename file | Saku Ytti | |
2015-03-26 | remove whitespace, rename class | Saku Ytti | |
2015-03-23 | Backup full ASA configuration (include passwords) | Stefan Schlesinger | |
At the old version it didn't backup things like ldap passwords, which ended up in output marked as '****'. pre: ldap-login-password ***** now: ldap-login-password wBGqqqCY5SjZ8hY | |||
2015-03-16 | Remove traces of telnet support | Eric | |
2015-03-16 | Added support for Mikrotik RouterOS | Eric | |
2015-03-14 | Also fix logout issue as described in #89 | Eric | |
2015-03-14 | Fix terminal length issues with older powerconnect switches as mentioned in ↵ | Eric | |
#89. Fixed by sending both commands and allowing one of them to fail. | |||
2015-03-07 | Add back ability to use passwordless enable on EOS | J. Brandt Buckley | |
This commit adds the ability to go into Privileged EXEC mode when no password is required by setting `enable: true`. By default, in Arista EOS you aren't prompted for a password when entering Privileged EXEC (or privilege mode 15) mode. In PR #86, oxidized began always expecting a password. An unquoted `true` in YAML is a boolean. So when `var(:enabled)` is `TrueClass`, we interpret this as meaning that the user wishes to go into Privileged EXEC mode and does not require a password. | |||
2015-03-03 | fixes for EOS switches with enable secret configured | Martin Pels | |
2015-02-27 | better prompt for Arista EOS | Samer Abdel-Hafez | |
2015-02-27 | Minor cosmetic changes and additions | Samer Abdel-Hafez | |
2015-02-24 | set_cmd can't be nil | Saku Ytti | |
still not sure if this is the right way to guard non-string blocks... | |||
2015-02-23 | guard against model returning non-string | Saku Ytti | |
Return empty string instead of what ever model returned. Closes #63 | |||
2015-02-19 | Logout behaviour fixed. | fhibler | |
2015-02-19 | Password detection fixed | fhibler | |
2015-02-07 | Added model for Comware based devices | Jasper | |
Added support for Comware based devices from HP (A-series), H3C and 3Com. | |||
2015-01-20 | stop Aruba changing the diff each 'show inventory' | Charlie Allom | |
Also fix the boilerplate comment to reflect the OEM relationship | |||
2014-12-03 | Merge branch 'master' into cfg_as_object | Saku Ytti | |
2014-10-27 | model/asa: ASA prompt contains HA Failover state separated by slashes | Stefan Schlesinger | |
2014-10-23 | model/asa: removing >show clock and ignoring uptime in >show version | Stefan Schlesinger | |
2014-10-23 | model/asa: fixing prompt - hostname regex taken from ios model | Stefan Schlesinger | |
2014-10-02 | Fixed more ever changing output in powerconnect model, only shows up on some ↵ | Eric | |
firmware versions | |||
2014-09-26 | Removed ever-changing output from powerconnect model, thanks @artmann | Eric | |
2014-09-22 | Added model for cisco NXOS | Eric | |
2014-09-22 | Fixed small bug in powerconnect enable code | Eric | |
2014-08-30 | Remove ntp clock-period completely | Saku Ytti | |
emj complained that it sometimes pops in, sometimes pops out. I guess really no point having it there. | |||
2014-08-24 | Add Brocade NOS | Saku Ytti | |
2014-08-24 | Add ExtremeXOS | Saku Ytti | |
2014-08-19 | Merge branch 'master' into cfg_as_object | Saku Ytti | |
2014-08-18 | Add model for Cisco small business switches | Matthew Boehlig | |
Supports 200, 300, 500, and ESW2 series switches | |||
2014-08-16 | Merge branch 'master' into cfg_as_object | Saku Ytti | |
2014-08-15 | Added enable magic for powerconnect model, fixed pagination issues | Eric | |