summaryrefslogtreecommitdiff
path: root/lib/oxidized/model
AgeCommit message (Collapse)Author
2017-02-17add software versionbyq
added software version
2017-02-16Merge pull request #728 from mediumo/tplinkytti
Tplink model
2017-02-16changed README and enable behaviour to cmd instead of sendroot
2017-02-16added variable fortios_autoupdate, to control inclusion of autoupdate messagesroot
2017-02-16added tplink modelroot
2017-02-16added psk and private-key removal to secret sectionroot
2017-02-14Updated timos.rb to ignore "Generated" and "Finished" lines so it doesn't ↵Tim Pozar
look like a new config each time to crawls the box.
2017-02-14Update opengear.rbboudreau
With new update : OpenGear/CM71xx Version 3.16.6u1 e02e2d59 -- Mon Nov 14 17:44:05 EST 2016 the backup wasn't working anymore, needed a prompt
2017-02-10nxos.rb: Add secret blockDave
Took config from our local setup. Adding since it does not have it
2017-02-10Merge pull request #712 from Ultra2D/issue-681ytti
Procurve convert next line (NEL) to new line
2017-02-10Procurve convert next line (NEL) to new lineUltra2D
2017-02-10Remove (some) secrets from Comware configUltra2D
2017-02-07Merge branch 'master' into ArubaIAP_MASTim Pray
2017-02-07Better notes and fix a mistake in the secret linesTim Pray
2017-02-07Modify to support IAP, Instant Controller and Mobility Access SwitchesTim Pray
2017-02-06changed "diagnose autoupdate version" behaviour, since with every update of ↵root
signatures the config version is changed
2017-02-06nicer regex for both password variants of fortiOSroot
2017-02-06added secret removal for fortiOSroot
2017-02-04Cleaner way to fix older IronWare devicesJason Wendel
This works on older IronWare devices without needing a sleep between each command.
2017-02-03Restore compatibility with older versions of IronWareJason Wendel
Remove \r from the "enable" command. Both \r and \n are interpreted the same on older versions, causing a blank line to be sent as the enable password. Add a delay between the sending of the "logout" command and each "exit" command. Older devices don't seem to be able to keep up with the speed the commands are sent without a delay.
2017-02-03Update fabricos.rbK. Gasso
Ignore Uptime/Power/Date fields in chassisShow and configShow
2017-01-31Filter out rogue client alerts from AireOSRoss W
2017-01-24Don't show error is unsupportedvppencilsharpener
This is the proposed fix for issue #669. Let me know if there is anything that I need to fix. This appears to be working correctly for the switch I have in house (S2400-24P). However the model is not working for the Aruba Instant AP (IAP) (virtual) controller. I hope to submit a fix for those once I have it working. The problems with that device appear to be unrelated to these changes as the prompt is incorrect.
2017-01-19Tweak the white space for cleaning.vppencilsharpener
2017-01-18Update ironware.rbdevicenull
Some Brocade devices only have two possible fan speeds. Previously, this only handled three levels of fan speeds. Updated regex will handle both of these cases: Fan 1 ok, speed (auto): 1<->[[2]] Fan 1 ok, speed (auto): 1<->[[2]]<->3
2017-01-11Ignore fan speed changes for ironwaredevicenull
Brocade ICX/FCX log fan speed changes like this: Fan ok, speed (auto): 1<->[[2]]<->3 Fan ok, speed (auto): [[1]]<->2<->3 Remove the current fan speed from the configuration to prevent lots of useless changes from being logged.
2017-01-10Ensure config gets returned even if no replacements are donedevicenull
2017-01-10Mask out configuration date for fiberdriverdevicenull
Our fiberdriver devices report a timestamp during 'show running-config', which results in a config diff on every run. This patch removes the '+! Configuration saved on 2017/01/10 14:21:20' line from the config, as well as a couple other useless status messages
2017-01-10Add support for telnetJason Lixfeld
2017-01-09Ignore undefined UTF8 in ironware.rbdevicenull
We have some Brocade MLX devices that are triggering 'raised Encoding::UndefinedConversionError with msg ""\xFF" from ASCII-8BIT to UTF-8"'. Update the ironware.rb file to ignore undefined UTF8 as well as invalid UTF8
2017-01-09adding zhone OLT/MX GPON/MetroE/DSL gearRobert Drake
2016-12-27Hide remaining passwordsGaëtan DUCHAUSSOIS
2016-12-27Update ios.rbGaëtan Duchaussois
Do the terminal configure after enable since it might be prohibited in non ena
2016-12-14delete secret password if it is called secretmattttv
2016-12-07Fix suggested by ytti for issue #610Mike Rostermund
2016-12-07Remove trailing whitespace and enable prompt detectionThane Gill
Fixes: #630
2016-12-06Update eos.rbjbaker48
2016-12-06exclude time from outputjbaker48
2016-11-18Update ciscosmb.rbAtroskelis
Added old commands in case of different CLI variations.
2016-11-18Update ciscosmb.rbAtroskelis
Forgot the username prompt change.
2016-11-18Update ciscosmb.rbAtroskelis
Adapted for SG series, not sure about SF. Please test.
2016-11-11expect prompt after entering enable passwordSaku Ytti
2016-11-10add support for PLANET SG switchesFlorian Klink
So far, only SGS switches were supported. Now, we check the model type during the 'show version' command, and only execute the 'show transceiver details' command in case an SGS switch was detected (as its not supported on SG models). We will also strip lines containing the current System Time and Uptime. These only appear on SG models, but it's a good idea to strip them anyways.
2016-11-09renamed alvarion -> alvarion.rbRobert Drake
I believe from this: require File.join dir, file+'.rb' That the only way this model would work is if it has a .rb extension. I don't have any of these devices to test if this works.
2016-11-07Merge pull request #606 from rfdrake/dlinkytti
This adds support for D-Link switches
2016-11-04Merge pull request #608 from rfdrake/trangoytti
Added support for Trango/Trangolink-45
2016-11-04Merge pull request #607 from rfdrake/hatterasytti
This adds support for Hatteras Networks devices
2016-11-04This adds support for Hatteras Networks devicesRobert Drake
2016-11-04This adds support for D-Link switchesRobert Drake
This specifically supports DES-3526/3550 series switches.
2016-11-04This adds support for the Casa C1G CMTSRobert Drake
This will probably work for the other Casa CMTS as well.