class AOSW < Oxidized::Model
# AOSW Aruba Wireless, IAP, Instant Controller and Mobility Access Switches
# Used in Alcatel OAW-4750 WLAN controller
# Also Dell controllers
# HPE Aruba Switches should use a different model as the software is based on the HP Procurve line.
# Support for IAP & Instant Controller tested with 115, 205, 215 & 325 running 6.4.4.8-4.2.4.5_57965
# Support for Mobility Access Switches tested with S2500-48P & S2500-24P running 7.4.1.4_54199 and S2500-24P running 7.4.1.7_57823
# All IAPs connected to a Instant Controller will have the same config output. Only the controller needs to be monitored.
comment '# '
prompt /^\(?.+\)?\s[#>]/
cmd :all do |cfg|
cfg.each_line.to_a[1..-2].join
end
cmd :secret do |cfg|
cfg.gsub!(/secret (\S+)$/, 'secret <secret removed>')
cfg.gsub!(/enable secret (\S+)$/, 'enable secret <secret removed>')
cfg.gsub!(/PRE-SHARE (\S+)$/, 'PRE-SHARE <secret removed>')
cfg.gsub!(/ipsec (\S+)$/, 'ipsec <secret removed>')
cfg.gsub!(/community (\S+)$/, 'community <secret removed>')
cfg.gsub!(/ sha (\S+)/, ' sha <secret removed>')
cfg.gsub!(/ des (\S+)/, ' des <secret removed>')
cfg.gsub!(/mobility-manager (\S+) user (\S+) (\S+)/, 'mobility-manager \1 user \2 <secret removed>')
cfg.gsub!(/mgmt-user (\S+) (root|guest\-provisioning|network\-operations|read\-only|location\-api\-mgmt) (\S+)$/, 'mgmt-user \1 \2 <secret removed>') #MAS & Wireless Controler
cfg.gsub!(/mgmt-user (\S+) (\S+)( (read\-only|guest\-mgmt))?$/, 'mgmt-user \1 <secret removed> \3') #IAP
#MAS format: mgmt-user <username> <accesslevel> <password hash>
#IAP format (root user): mgmt-user <username> <password hash>
#IAP format: mgmt-user <username> <password hash> <access level>
cfg.gsub!(/key (\S+)$/, 'key <secret removed>')
cfg.gsub!(/wpa-passphrase (\S+)$/, 'wpa-passphrase <secret removed>')
cfg.gsub!(/bkup-passwords (\S+)$/, 'bkup-passwords <secret removed>')
cfg.gsub!(/user (\S+) (\S+) (\S+)$/, 'user \1 <secret removed> \3')
cfg.gsub!(/virtual-controller-key (\S+)$/, 'virtual-controller-key <secret removed>')
cfg
end
cmd 'show version' do |cfg|
cfg = cfg.each_line.select { |line| not line.match /(Switch|AP) uptime/i }
rstrip_cfg comment cfg.join
end
cmd 'show inventory' do |cfg|
cfg = "" if cfg.match /(Invalid input detected at '\^' marker|Parse error)/ #Don't show for unsupported devices (IAP and MAS)
rstrip_cfg clean cfg
end
cmd 'show slots' do |cfg|
cfg = "" if cfg.match /(Invalid input detected at '\^' marker|Parse error)/ #Don't show for unsupported devices (IAP and MAS)
rstrip_cfg comment cfg
end
cmd 'show license' do |cfg|
cfg = "" if cfg.match /(Invalid input detected at '\^' marker|Parse error)/ #Don't show for unsupported devices (IAP and MAS)
rstrip_cfg comment cfg
end
cmd 'show running-config' do |cfg|
out = []
cfg.each_line do |line|
next if line.match /^controller config \d+$/
next if line.match /^Building Configuration/
out << line.strip
end
out = out.join "\n"
out << "\n"
end
cfg :telnet do
username /^User:\s*/
password /^Password:\s*/
end
cfg :telnet, :ssh do
if vars :enable
post_login do
send "enable\n"
cmd vars(:enable)
end
end
post_login 'no paging'
post_login 'encrypt disable'
if vars :enable
pre_logout 'exit'
end
pre_logout 'exit'
end
def rstrip_cfg cfg
out = []
cfg.each_line do |line|
out << line.rstrip
end
out = out.join "\n"
out << "\n"
end
def clean cfg
out = []
cfg.each_line do |line|
# drop the temperature, fan speed and voltage, which change each run
next if line.match /Output \d Config/i
next if line.match /(Tachometers|Temperatures|Voltages)/
next if line.match /((Card|CPU) Temperature|Chassis Fan|VMON1[0-9])/
next if line.match /[0-9]+\s+(RPMS?|m?V|C)/i
out << line.strip
end
out = comment out.join "\n"
out << "\n"
end
end
|